Laurie Poulter at Happy Drains, a drainage services business, looks at how facilities teams organise and retain useful information when a maintenance contract changes hands, and offers a practical framework for discussing a handover with contractors and colleagues.

When a facilities contract changes hands, drainage knowledge can disappear with it. A portable handover file helps the incoming team find assets, understand work and identify gaps before commissioning more.



Start With A File The Client Can Keep

A contractor change should not force the facilities team to rebuild its drainage history from invoices and personal inboxes. Before the outgoing team leaves, agree what information will transfer, where it will be stored and who will maintain it afterwards.

The file should belong in a location the client can continue to access. A shared folder or existing asset system may be sufficient. The test is whether an authorised colleague can find a particular drainage asset and its records without relying on the outgoing contractor's account or memory.


Give Each Access Point A Stable Reference

Use consistent references for the access points already recorded on the site. Pair each reference with a location description and, where available, a marked plan or existing photograph. Avoid replacing established labels without keeping a cross-reference to the old ones.

A chamber described as “behind the building” may be obvious to a regular engineer but ambiguous to a new team. A useful description identifies the building, nearby landmark and relevant access arrangements. Mark uncertain locations as unconfirmed rather than presenting an assumption as a surveyed fact. This is a records exercise, not an instruction for staff to lift covers or enter chambers.


Link The Work History To The Asset

Keep attendance reports, survey findings and completion records alongside the asset reference. Record the date, contractor, reason for attendance and section of pipework examined or worked on. A single incident may involve several assets; preserve those connections instead of forcing everything under one convenient label.

Distinguish what the contractor observed from what was inferred. Restoring flow does not, by itself, establish the underlying cause. If a report recommends repair, retain the evidence and limitations supporting that recommendation. Where a section could not be inspected, make the gap visible to the incoming team.


Test That The Evidence Still Opens

Survey reports are less useful if their supporting footage remains behind an expired download link. Ask for copies in formats the organisation can retain and reopen, with any necessary viewing instructions. Check that the filenames and report references make it possible to connect footage to the relevant route.

Before handover, open a sample of the files from the account or device the incoming team will actually use. Confirm that access permissions work and that an external contractor's departure will not remove the only copy. Keep the original evidence and record subsequent corrections separately so changes remain traceable.


Separate Responsibility From Access

A plan showing a drain is not proof that the facilities contractor is responsible for maintaining it. Record confirmed ownership or maintenance arrangements, the source of that information and any unresolved questions. Check the particular pipework against site records, contracts and the sewerage company where appropriate.

Access information should include existing permits, site contacts, operational restrictions and known hazards. A location photograph does not replace an assessment of the work. HSE guidance calls for avoiding confined-space entry where possible and taking appropriate precautions where entry is necessary. Handover records should help competent people plan safely, without encouraging untrained staff to investigate chambers themselves.


Carry Forward Open Decisions

Create a short list of unresolved items: a recommended survey that has not been commissioned, an incomplete inspection, a recurring incident awaiting review or a responsibility question still being checked. Give each item an owner and a next action. Separate proposed work from approved work so the incoming contractor does not mistake a quotation for an instruction.

At the handover meeting, choose one recurring problem and follow its record from the initial incident through to the latest decision. If the evidence cannot be found or the reasoning is unclear, repair the file before accepting it as complete. This small exercise tests the handover more effectively than counting documents.


Make The File Part Of The Next Contract

Agree how future attendances will update the same record, including naming conventions, required report fields and who checks completeness. Keep access limited to people who need it and remove unnecessary personal information from shared copies.

The objective is continuity: a facilities team should be able to change supplier while retaining a clear account of its assets, previous work and outstanding decisions. A handover file earns its place when someone unfamiliar with the site can use it to ask the right next question.


Picture: An image of a Happy Drains service van parked on the kerb in a residential area.

Article written by Laurie Poulter | Published 17 November 2026

Share



Related Articles

Jet Through Wins Drainage Works Contract With Greene King

Jet Through has won its bid to provide drainage services to one of the UK’s largest pub and brewery chains, Greene King. The three-year contract will see...

 Read Full Article
UK Businesses Are Overlooking A Growing Infrastructure Risk Beneath Their Feet

The UK’s drainage infrastructure is under mounting pressure from age, demand and neglect. Much of the network is still rooted in Victorian-era design and is now...

 Read Full Article
Why Siphonic Drainage Systems Are The Smart, Sustainable Choice For Facilities Managers

Hannah McNamee, Service Sales Manager at Capcon Engineering, discusses siphonic systems and how they can reduce risk, support ESG goals and help FMs run a more...

 Read Full Article
PTSG Launches New Siphonic Health Check Tool

NSS, part of PTSG, has launched a free online Siphonic Health Check tool to help building owners, facilities managers and property professionals understand whether...

 Read Full Article
Mecsia Acquires The Drain Group

Technical services provider Mecsia has completed its acquisition of The Drain Group, a drainage specialist operating across the West Midlands. The Drain Group will...

 Read Full Article
London Drainage Facilities Completes First Acquisition of 2025

London Drainage Facilities has acquired Lewes-based drainage and plumbing services provider BlockBusters. This will allow London Drainage Facilities to expand its...

 Read Full Article
Spotlight Interview – Danny Fuller | London Drainage Facilities

Danny Fuller is the Operations Director of London Drainage Facilities. Established in 2006, London Drainage Facilities has quickly become one of London’s leading...

 Read Full Article
Thermatic Acquires PDS Drainage Solutions

Technical FM provider Thermatic has acquired PDS Drainage Solutions. PDS’ position in the commercial drainage market in the UK will aid Thermatic’s’...

 Read Full Article