The Leading News & Information Service For The Facilities, Workplace & Built Environment Community

The Classification Game: Why ‘Extra Care’ Isn’t ‘Care’

The Classification Game: Why ‘Extra Care’ Isn’t ‘Care’
24 September 2026 | Updated 22 September 2026
 

Iain Cox, Chairman of the Business Sprinkler Alliance (BSA), continues to press the case for a fundamental rethink of how fire safety regulations treat housing for vulnerable people. At the heart of the issue lies a simple but consequential question: what counts as a ‘care home’?

Recent updates to Approved Document B (ADB) and Technical Booklet E mean that, where a building is registered as a care home, sprinkler systems are now mandatory for new builds. On paper, this looks like progress. In practice, it only tells part of the story.



Extra care housing, the model under which Beechmere Retirement Village1 operated before the devastating fire that destroyed it in 2019, simply doesn't fall into this bracket. Despite housing elderly and often less mobile residents, many of whom require regular care and assistance, extra care schemes are typically classified in regulatory terms as something in a grey zone. The result is that a building can be functionally indistinguishable from the characteristics of a care home in terms of who lives there and what assistance they may need in a fire, yet sit entirely in a blind spot in the regulatory guidance when it comes to the use of sprinkler protection.

This isn't a new observation. The BSA has raised it before, and the recent proposed amendments to ADB have done nothing to close it. For extra care facilities, the proposal is for enhanced fire detection and a definition change. Outside this, the guidance remains the same regardless of the realities of who actually lives in these buildings and how quickly they could evacuate in an emergency.

The frustrating part is that government is not unaware of this gap. There has been activity, consultations, statements, and research, but activity is not the same as action. From where the BSA sits, it increasingly looks like the cards are being shuffled rather than the underlying problem being addressed. Definitions get tweaked, guidance documents get amended at the margins, but the core inconsistency, that two buildings housing equally vulnerable people can be treated entirely differently depending on a classification on paper, remains untouched.

Regulator-commissioned research into this area has also left much to be desired. The BSA finds it odd that despite making so many observations, the research produced inconclusive and contradictory findings on fire alarms. It's fair to say this has not given the sector the clarity or direction it needs. In regards to the question of sprinklers, this was pushed into the future of some unknown ‘phase 2’ which, again, is odd as this would have been one of the key tasks for the research in the first place. Where there was an opportunity to properly interrogate the risks faced by extra care residents and recommend a proportionate regulatory response, what has emerged instead feels like a missed opportunity, falling short of giving policymakers the evidence base required to act decisively.

This matters because the population living in extra care housing is growing. As the UK's demographic profile shifts and more people choose or are guided towards these models of independent-but-supported living, the number of people potentially affected by this regulatory blind spot will only increase. Waiting for another Beechmere-scale incident to force change is not an acceptable approach. Slamming the stable door is a poor substitute for rational regulation.

The BSA's position remains consistent: classification should not be the determining factor in whether a building receives life-saving fire protection. The characteristics of the people living there, their age, mobility, and reliance on assistance, should be central to the conversation. The BSA urges government to look again, thoroughly and rationally, at where extra care facilities sit in the fire safety landscape, to ensure that future guidance reflects the needs of residents rather than the convenience of categorisation.


1. Fire at Beechmere Retirement Village – see here.


Picture: A black-and-white image of three hands resting together in a gesture of care. Credit: Thomas Griggs.

Article written by Dave Mapps | Published 24 September 2026

Share



Related Articles

Seven Fire Safety Myths That Could Put Your Business At Risk

As commercial buildings continue to adapt through refurbishments, changing occupancy levels and evolving workplace practices, fire safety planning also needs to evolve....

 Read Full Article
Regulation 10 Three Years On: Keeping Up With Fire Door Checks

Kemble Nagan, Managing Director at DoorTRACE, notes that January marked three years since Regulation 10 of the Fire Safety (England) Regulations 2022 came into force. For...

 Read Full Article
The Hidden Carbon Cost Of Infrastructure Loss

Sustainability reporting across major infrastructure has become increasingly sophisticated. Airports and transport hubs now measure greenhouse gas (GHG) emissions across...

 Read Full Article
Housing Association Clarion Instructed Staff to Fake Fire Safety Notices

A Sky News investigation has revealed that a manager at Clarion Housing encouraged an employee to falsify a fire safety notice in one of the housing association’s...

 Read Full Article
Company Fined £165,000 for ‘Blatant Disregard’ for Fire Safety in Preston Redevelopment 

A construction firm has been fined for repeatedly ignoring fire safety precautions during the conversion of a Preston warehouse into residential apartments. Lancashire...

 Read Full Article
Campaign Groups Urge Sadiq Khan to Halt Tower Block With One Staircase

The Fire Brigades Union and other groups have written to Sadiq Khan and Bromley Council leader Colin Smith, raising concerns over plans for a 17.7-metre-high development...

 Read Full Article
What We Know so Far About the Valencia Apartment Block Fire

Emergency services have attended the scene of a fire at a high-rise apartment complex in Valencia, Spain  The fire occurred on Thursday 22 February at a...

 Read Full Article
59% of Business Electrical Fires Caused by Faulty Equipment

Data from UK fire and rescue authorities has identified the number of electrical fire-related callouts to businesses. Using statistics from 32 fire and...

 Read Full Article
Kings Secure Technologies Acquires EFire

Kings Secure Technologies is to acquire UK fire and life safety systems provider East Fire Extinguishers and Alarms. First established in 2011 and headquartered in...

 Read Full Article
LHC Launches New Fire Safety Framework

Procurement consortium LHC is asking fire safety experts to get involved in the new Fire Safety (FS2) Framework. FS2 covers the end-to-end spectrum of fire safety...

 Read Full Article