Legionnaires’ Disease - Identifying Breakthrough

Idexx Legiolert test
02 November 2018
 

An independent water study has shown increased accuracy of the Idexx Legiolert test in identifying Legionnaires’ disease risk over current methods.

Idexx, a leader in the field of rapid microbiological testing for water, has shared the results of a new potable water study carried out by independent water microbiology experts.

 

International Journal of Hygiene and Environmental Health

The study, “Comparison of Legiolert/Quanti-Tray MPN test for the enumeration of Legionella pneumophila from potable water samples with the German regulatory requirements methods ISO 11731-2 and ISO 11731', was recently published in the International Journal of Hygiene and Environmental Health. The study concludes: 'the new method (Quanti-Tray/Legiolert) represents a significant improvement in the enumeration of L. pneumophila from drinking water and related samples'.

 

Cause

L. pneumophila causes 97% of Legionnaires’ disease cases according to data from cultures of 4,719 patients over seven years in 17 countries (according to the European Centers for Disease Control data).

Within the comparison study, six accredited laboratories, including hospitals, a water company, and commercial laboratories compared Legiolert and the German combined ISO 117311 - 1 / 2 approach for the enumeration of Legionella pneumophila, over the period of August 2016 to March 2017.

The study found the IDEXX Legiolert method to be significantly more sensitive for the recovery of L. pneumophila for 100mL samples compared to the ISO 11731-2 method, and states that Legiolert could be an acceptable and potentially superior alternative to the combined current German ISO 11731-2/ISO 11731 testing procedure.

Legiolert also recorded a significantly greater number of positive samples for the 100 mL sample test volume, and additionally provided counts of L. pneumophila that were not statistically different than the ISO 11731-2 method provided for all species of Legionella.

On a presence-absence basis, the study found that the ISO 17731-2 method was twice as likely to miss positive samples as Legiolert, including samples that were above the German action limit. The study also evaluated the practicality of the Legiolert method, finding that it demonstrated advantages such as ease of use and labour saving.

Picture: An study has shown increased accuracy of the Idexx Legiolert test in identifying Legionnaires’ disease.

 

Article written by Brian Shillibeer | Published 02 November 2018

Share



Related Articles

Legionnaires’ Outbreak Followed by Explosion Leads To £1.6 Million Fine

A manufacturer has been fined £1.6 million after a Legionnaires’ disease outbreak and an explosion occurred at the same plant within a year. The Health and...

 Read Full Article
Legionella Death Sees Massive Trust Fine

An NHS Trust has been £300,000 for the death of a patient from Legionnaires' disease and not managing its water systems correctly. In separate cases - a...

 Read Full Article
Revision to Legionnaires' Disease Guide

BSRIA has published its new Legionnaires’ Disease Risk Assessment guide. Legionnaires’ Disease – Risk Assessment (BG57/2015) has been written to provide...

 Read Full Article